High Performance 36 Volt Power Supply - 220W Dual Output equipment Power Supply – Huyssen
High Performance 36 Volt Power Supply - 220W Dual Output equipment Power Supply – Huyssen Detail:
Features:
Huyssen Daul Output Voltage Power Supply
Universal AC input : 90-264V
Cooling by free air convection
All using 105°C long life electrolytic capacitors
High operating temperature up to 70°C
High efficiency, long life and high reliability
LED indicator for power on
Full load high temperature burn-in, 100% burn-in test
Protections: Short circuit / over current / Overload / Over voltage
24 months warranty
Specifications:
MODEL |
HSJ-220-2412 |
HSJ-220-3612 |
HSJ-220-4812 |
||||
OUTPUT | OUTPUT NUMBER |
CH1 |
CH2 |
CH1 |
CH2 |
CH1 |
CH2 |
DC VOLTAGE |
12V |
24V |
36V |
12V |
48V |
12V |
|
RATED CURRENT |
5A |
6.6A |
3.A |
9A |
2.5A |
8A |
|
RATED POWER |
220W |
220W |
220W |
||||
RIPPLE&NOISE |
120mVp-p |
240mVp-p |
300mVp-p |
120mVp-p |
400mVp-p |
120mVp-p |
|
VOLTAGETOLERANCE |
±2.0% |
±6.0% |
±2.0% |
±5.0% |
±4.0% |
±4.0% |
|
LINEREGULATION |
±0.5% |
±1.5% |
±0.5% |
±1.0% |
±0.5% |
±0.5% |
|
LOADREGULATION |
±0.5% |
±3.0% |
±0.5% |
±2.0% |
±3.0% |
±3.0% |
|
SETUP.RISEHOLD.TIME | 500ms, 30ms/230VAC 1200ms, 30ms/115VAC at full load | ||||||
HOLD TIME | 80ms/230VAC 16ms/115VAC at full load | ||||||
INPUT | VOLTAGE RANGE | 90 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) | |||||
FREQUENCYRANGE | 47~63HZ | ||||||
EFFICIENCY |
86% |
82% |
80% |
||||
AC CURRENT | 0.8A/115VAC 0.55A/230VAC | ||||||
INRUSH CURRENT | COLD START 36A/230VAC | ||||||
LEAKAGECURRENT | <2mA/240VAC | ||||||
PROTECTION | OVERLOAD | 110~150% rated output power | |||||
Protection type: Hiccup mode,recovers automatically after fault condition is removed | |||||||
OVER VOLTAGE | YES | YES | |||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||||
ENVIRONMENT | WORKING TIMP | -25~+70°C (Refer to “Derating Curve”) | |||||
WORKINGHUMIDITY | 20~90% RH non-condensing | ||||||
STORAGE TEMP HUMIDITY | -40~+85°C 10~95%RH | ||||||
TEMPCOEFFICIENT | ±0.03%/ °C(0~50°C) on CH1 output | ||||||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes | ||||||
SAFETY&EMC | SAFETYSTANDARDS | U60950, TUV EN60950 approved | |||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||||
ISOLATIONRESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH | ||||||
EMC EMISSION | Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 | ||||||
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A | ||||||
QTHERS | MTBF | 179Khrs min. MIL-HDBK-217F (25°C ) | |||||
DIMENSION | 160*78*40mm (L*W*H) | ||||||
PACKING | 0.8Kg; 20PCS/11Kg |
Applications:
Industrial control equipment, self-service terminal equipment, medical equipment, communication equipment, animation products, game consoles, beauty equipment, etc.
Applications for power supply
Packing & Delivery
Certifications
Product detail pictures:




Related Product Guide:
We have probably the most state-of-the-art output equipment, experienced and qualified engineers and workers, recognized good quality manage systems plus a friendly skilled income workforce pre/after-sales support for High Performance 36 Volt Power Supply - 220W Dual Output equipment Power Supply – Huyssen , The product will supply to all over the world, such as: Turkmenistan, Milan, Tunisia, Our company has always insisted on the business principle of "Quality, Honest, and Customer First" by which we have won the trust of clients both from at home and abroad. If you are interested in our products, please do not hesitate to contact us for further information.