Dual Output 120W 15V 30V Equipment Power Supply
Features:
• Huyssen 15V -15V Triple Output Voltage Power Supply
• Universal AC input : 100-264V
• Cooling by free air convection
• All using 105°C long life electrolytic capacitors
• High operating temperature up to 70°C
• High efficiency, long life and high reliability
• LED indicator for power on
• Full load high temperature burn-in, 100% burn-in test
• Protections: Short circuit / over current / Overload / Over voltage
• 24 months warranty
		    
			Specifications:
| 
 MODEL  | 
 HSJ-120-2412  | 
 HSJ-120-0512  | 
 HSJ-120-1530  | 
||||
| OUTPUT | OUTPUT NUMBER | 
 CH1  | 
 CH2  | 
 CH1  | 
 CH2  | 
 CH1  | 
 CH2  | 
| DC VOLTAGE | 
 12V  | 
 24V  | 
 5V  | 
 12V  | 
 15V  | 
 30V  | 
|
| RATED CURRENT | 
 3A  | 
 3A  | 
 5A  | 
 8A  | 
 4A  | 
 2A  | 
|
| RATED POWER | 
 120W  | 
 120W  | 
 120W  | 
||||
| RIPPLE&NOISE | 
 120mVp-p  | 
 240mVp-p  | 
 80mVp-p  | 
 240mVp-p  | 
 150mVp-p  | 
 280mVp-p  | 
|
| VOLTAGEADJ.RANGE | 
 CH1: 4.75~5.5V  | 
 CH1: 4.75~5.5V  | 
 CH1: 13.5 ~ 16.5V  | 
||||
| VOLTAGETOLERANCE | 
 ±2.0%  | 
 ±6.0%  | 
 ±2.0%  | 
 ±5.0%  | 
 ±4.0%  | 
 ±4.0%  | 
|
| LINEREGULATION | 
 ±0.5%  | 
 ±1.5%  | 
 ±0.5%  | 
 ±1.0%  | 
 ±0.5%  | 
 ±0.5%  | 
|
| LOADREGULATION | 
 ±0.5%  | 
 ±3.0%  | 
 ±0.5%  | 
 ±2.0%  | 
 ±3.0%  | 
 ±3.0%  | 
|
| SETUP.RISEHOLD.TIME | 500ms, 30ms/230VAC 1200ms, 30ms/115VAC at full load | ||||||
| HOLD TIME | 80ms/230VAC 16ms/115VAC at full load | ||||||
| INPUT | VOLTAGE RANGE | 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) | |||||
| FREQUENCYRANGE | 47~63HZ | ||||||
| EFFICIENCY | 
 86%  | 
 82%  | 
 86%  | 
||||
| AC CURRENT | 0.8A/115VAC 0.55A/230VAC | ||||||
| INRUSH CURRENT | COLD START 36A/230VAC | ||||||
| LEAKAGECURRENT | <2mA/240VAC | ||||||
| PROTECTION | OVERLOAD | 110~150% rated output power | |||||
| Protection type: Hiccup mode,recovers automatically after fault condition is removed | |||||||
| OVER VOLTAGE | YES | YES | |||||
| Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||||
| ENVIRONMENT | WORKING TIMP | -25~+70°C (Refer to "Derating Curve") | |||||
| WORKINGHUMIDITY | 20~90% RH non-condensing | ||||||
| STORAGE TEMP HUMIDITY | -40~+85°C 10~95%RH | ||||||
| TEMPCOEFFICIENT | ±0.03%/ °C(0~50°C) on CH1 output | ||||||
| VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes | ||||||
| SAFETY&EMC | SAFETYSTANDARDS | U60950, TUV EN60950 approved | |||||
| WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||||
| ISOLATIONRESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH | ||||||
| EMC EMISSION | Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 | ||||||
| EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A | ||||||
| QTHERS | MTBF | 179Khrs min. MIL-HDBK-217F (25°C ) | |||||
| DIMENSION | 150*55*40mm (L*W*H) | ||||||
| PACKING | 0.4Kg; 20PCS/9Kg | ||||||
120W power supply widely used in:
● LED light bar, light strip, LED luminous characters, LED display, LED billboard, liquid crystal display, massager, module, lighting project, various light boxes, etc.;
● Monitoring security equipment, industrial equipment, routers, motors, cameras, tablet computers, projection equipment, power amplifiers, navigation integrated machines, building intercom systems, etc.
Applications for power supply
		    
			
		    
			
		    
			
		    
			
		    
			
		    
			
		    
			
		    
			Packing & Delivery
		    
			
		    
			
		    
			
		    
			
		    
			Certifications
		    
			
		    
			
		    
			
		    
			
		    
			
		    
			
		    
			
		    
			
                